Appliance Error Code Guide Codes, causes & fix order
Dryers · Whirlpool

Whirlpool Dryer Error Codes: AF, PF, L2 and the Pairs

Whirlpool is sparing with dryer codes, and that is helpful: three of them cover the faults an owner can actually fix, and anything with an F and an E in it is the machine telling you to stop and call someone.

Checked against Whirlpool product help documentation Updated 17 November 2026 8 min read

The short answer

  • AF / F4 E3 — restricted airflow. Clean the lint screen and the whole duct.
  • PF — power failure interrupted the cycle. Resume or clear it.
  • L2 — one leg of the electric supply is missing; the dryer runs but will not heat.
  • F# E# pairs — an internal fault. Note both halves and the model code before calling.

The codes

CodeMeaningWhat to do
AF or F4 E3Restricted airflow — lint screen, vent or crushed ductClean the screen, check the duct and the outside hood
PFPower failure during the cycleHold Start to resume, or press Power to clear
L2Low or no line voltage on one legCheck both breakers, the cord and the outlet
F01Primary control failureService — the control board is named
F22 / F23Exhaust thermistor open / shortedService — thermistor or harness
F26Motor drive system failureService — motor or drive circuit
F28 / F29Moisture sensor open / shortedOften only visible in diagnostic mode; the sensor strip or its wiring

Code numbering differs across Whirlpool's platforms, and Maytag, KitchenAid, Amana and some Kenmore dryers share it. Match the idea rather than the exact letters if your display shows something slightly different.

AF: the one that matters

  1. Clean the lint screen and wash it if it has a fabric-softener film. Hold it up to a light — if you cannot see through it, airflow is restricted at the first hurdle.
  2. Check the duct behind the machine for crushing and kinks. A flexible duct squashed against the wall is the most common cause of AF in a machine that has just been moved.
  3. Check the outside hood while the dryer runs. Flaps that do not open fully mean a blockage or a damaged hood.
  4. Clean the wall run with a duct brush, or have it done. Long runs with several elbows are where lint settles.
  5. Reduce the load so air can pass through the clothes from back to front.
Lint is fuel. A dryer with a restricted vent runs hotter than designed, and lint around the heater housing can ignite. Clean the full duct, not just the screen, and never vent a dryer into a room or a roof space.

L2 and the two-leg supply

An electric dryer in North America runs on a split supply: two live legs and a neutral. The motor and controls run on one leg, the heater on both. If one leg is lost — a tripped breaker, a blown cartridge fuse, a bad cord connection — the drum turns, the display works and nothing heats. L2 is the code that says so, and it usually appears first at installation.

Check both breakers, then the cord terminals at the machine for a loose or scorched connection. If the supply is sound and L2 persists, the control is the next suspect.

Diagnostic mode and the F codes

Most Whirlpool dryers have a diagnostic test mode entered from the control panel — typically a sequence of button presses listed on the tech sheet behind the console or in the manual. The mode runs the components in order and shows stored faults. F28 and F29 usually appear only there, because a moisture sensor fault does not stop the dryer.

If you are going to call a technician, note the full code pair, the model and serial number, and whether the fault appears in normal use or only in diagnostic mode. That information often decides whether the visit is a sensor or a board.

Repair or replace

AF costs nothing to fix and is the reason most owners think their dryer is failing. F-code repairs are parts-dependent: a thermistor is modest, a control board is not. Use the cost formula and remember that a dryer is one of the simpler appliances to replace.

Frequently asked questions

The dryer runs but clothes stay damp after two cycles — no code?

Airflow, a moisture sensor that needs cleaning, or a load that is too large. Clean the sensor bars inside the drum with a damp cloth and check the vent.

Can I clear AF without cleaning?

Touch any key and the display returns to the time remaining. The restriction has not changed.

Is a gas Whirlpool dryer different?

The codes are the same family. AF still points at airflow, but a gas dryer that will not heat needs the igniter and gas valve checked, which is technician work.

Sources

  1. Whirlpool product help — "Error Codes in Dryers" (AF/F4E3, PF, L2, F#E#), accessed 17 November 2026.
  2. Whirlpool tech sheet for a current platform, listing display fault codes F01, F22, F23, F26, F28 and F29.
  3. Editorial review against the parts trade: airflow faults after moving a machine, and L2 at installation.

General information only. Codes differ across Whirlpool platforms and rebadged brands. Confirm against your model's tech sheet or manual; gas and mains wiring belong to qualified technicians.